Lord Consulting - News
Interfacing On-line Monitoring Technologies to Power Transformers
Written by Written by Trevor LORD and Graham Hodge (LORD Consulting)   
Tuesday, 13 July 2010 07:53
Read more...
 
Mobile System For Diagnosis Of High Voltage Cables
Thursday, 06 May 2010 16:20

Mobile System For Diagnosis Of High Voltage Cables (132KV/220KV) VLF-200 HVED

Very Low Frequency (Vlf) - Partial Discharges And Tangent Delta HV/EHV Power Cables Diagnostic And On-Site Field Testing With VLF+PD+TD

Electrical Testing Group Inducor Ingenieria
Inducor Ingeniería S.A. – Buenos Aires Argentina – www.inducor.com.ar

Read more...
 
Application of Corona Imaging to MV & HV Insulator Management
Thursday, 04 December 2008 00:00

Instructions on how to get a copy of this paper can be found here

Read more...
 
Papers on the use of Corona camera technology
Tuesday, 17 June 2008 00:00

A new link has been added to papers on the use of Corona camera technology in the management of HV Transmission Lines.

Read more...
 
New Software released by Morgan Schaffer for Calisto
Monday, 07 May 2007 00:00
For your information, Morgan Schaffer has released a new version of their “Calisto Access” software.
Read more...
 
Using Gas-in-Oil Standards to Improve the Accuracy of DGA Results and Diagnosis
Friday, 19 January 2007 00:00

By M. Duval

Dissolved gas analysis (DGA) is widely used to monitor the condition of transformers and other pieces of oil-filled equipment in service. Wrong diagnoses may be drawn, however, if the DGA results coming from the lab are not accurate. For instance, an electrical fault may be mistaken as a thermal fault, which may have serious consequences for the equipment. Several CIGRE and IEC round robin tests (RRTs) have shown that the repeatability (precision) of DGA labs is generally good, but that their accuracy (deviation from true value) is often poor.

Read more...
 
Load Tap Changer (LTC) Position Indicators
Monday, 15 January 2007 00:00
LTC position monitors are IEDs that are used for monitoring a transformer’s tap position and changing it remotely based on fluctuations in the power load. The device converts the output of an electromagnetic position or displacement sensor (synchro transmitter) to a user-definable panel display and electrical output. The INCON Model 1250 for example employs a proprietary synchro conversion technique that is performed entirely in preprogrammed software. This approach uses few electrical components, thus ensuring a more stable and reliable output at a very reasonable cost.
Read more...
 
On-line Circuit Breaker Predictive Maintenance
Thursday, 07 December 2006 00:00

From a number of perspectives the active devices in an electric power delivery system, the circuit breakers, can be characterized as the weakest links in the network, as opposed to the passive components such as lines and transformers. That said, the unerring action of switching devices is critical to power delivery quality and reliability.

Read more...
 
Frequency Response Analysis (FRA)…
Monday, 27 November 2006 00:00

An impressive transformer assessment technology ready now!!
Input from Richard Breytenbach, South Africa:

Read more...
 